You are here: Home » Solar Energy System » Solar Energy System » Inverter & Controller » Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System

Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System

  • 3 Year

  • CE

  • 4kw-6kw

  • Model NO.: YHLS 4KW-6KW
  • Power Source: Solar Power
  • Nature of Wave String: Sine Wave Inverter
  • Transport Package: Netural Package
  • Specification: 530x335x150mm
  • Trademark: OEM
  • Origin: China
  • HS Code: 8504409940
  • Samples: US$ 800/Piece 1 Piece(Min.Order) | Request Sample
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
Welcome to YUANHE Import & Export One-Stop Solution of New Energy

Off-Grid & Hybrid Solar System / Energy Storage Saving
* Solar Panel (Glass / Folding)
* Inverter (Single Phase / Three Phase)
* Controller (MPPT / WMP)
* Rechargeable Battery (Lead Acid / Lipo4)
* Energy Storage Saving

Solar System Inverter Feature

1 Inverter pure sine wave output;
2 Low frequency toroidal transformer lower loss;
3 Intelligent LCD display;
4 AC charge current 0~30A adjustable, three working modes selectable;
5 Peak power more than 3 times, full-automatic and perfect protection function;
6 LS inverters added fault code query function, easy to monitor the operation in real time;
7 Supports diesel or gasoline generator, adapt any tough electricity situation;
8 Combine industrial and home usage, convenient to install.


Solar System Inverter Specification
Specification
Model LS 40224/48
(402)
50248
(502)
60248
(602)
Rated Power 4000W 5000W 6000W
Peak Power(20ms) 12000VA 15000VA 18000VA
Start Motor 3HP 4HP 4HP
Battery Voltage 24/48VDC 48VDC
Size(L*W*Hmm) 530*335*150
Packing Size(L*W*Hmm) 605*430*235
N.W.(kg) 22 24 26
G.W.(kg)(Carton Packing) 24 26 28
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) /
180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0~30A(Depends on model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature ≤55dB
Storage temperature -10ºC~40ºC
Noise -15ºC~60ºC
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice
Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System Solar Hybrid Inverter with Build-in MPPT/Wmp Charge Controller 4kw-6kw 24V/48V off-Grid Solar Energy System
Previous: 
Next: 
Jiangmen Yuanhe Import. and Export. Co.,Ltd .
We are not only professional product manufacturer, but also good at project solution.
ABOUT YUANHE
Our team has 17 years of experiences in Emergency lightings industry .We are professional in Emergency lightings / Intelligent Central Control System of Emergency Lightings /Solar System.

QUICK LINKS

NEWSLETTER
Be the first to receive updates on new arrivals, special promos and sales.
 
copyright© 2022 Jiangmen Yuanhe Import. and Export. Co.,Ltd . All Rights Reserved Sitemap Support by Leadong