You are here: Home » Solar Energy System » Solar Energy System » Inverter & Controller » Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System

Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System

  • 3 Year

  • CE

  • 4kw-7kw

  • Model NO.: YHWD 4kw-7kw
  • Power Source: Solar Power
  • Nature of Wave String: Sine Wave Inverter
  • Transport Package: Netural Package
  • Specification: 490x260x490mm
  • Trademark: OEM
  • Origin: China
  • HS Code: 8504409940
  • Samples: US$ 400/Piece 1 Piece(Min.Order) | Request Sample
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
Welcome to YUANHE Import & Export One-Stop Solution of New Energy

Off-Grid & Hybrid Solar System / Energy Storage Saving
* Solar Panel (Glass / Folding)
* Inverter (Single Phase / Three Phase)
* Controller (MPPT / WMP)
* Rechargeable Battery (Lead Acid / Lipo4)
* Energy Storage Saving

Solar System Inverter Feature

1 Pure sine wave output;
2 High efficiency toroidal transformer lower loss ;
3 Intelligent LCD integration display;
4 AC charge current 0-20A adjustable; battery capacity configuration more flexible;
5 Three types working modes adjustable:AC first, DC first, energy-saving mode;
6 Frequency adaptive function, adapt to different grid environments;
7 Added fault code query function,facilitate user to monitor the operation state in real time;
8 Supports diesel or gasoline generator, adapt any tough electricity situation;
9 Rechargeable power inverter with RS485 communication port/APP optional.


Solar System Inverter Specification
Specification
Model WD 40248/96
(402)
50248/96
(502)
60248/96
(602)
70248/96/192
(702)
Rated Power 4KW 5KW 6KW 7KW
Peak Power(20ms) 12KVA 15KVA 18KVA 21KVA
Start Motor 3HP 4HP 4HP 5HP
Battery Voltage 48/96VDC 48/96VDC 48/96VDC 48/96/192VDC
Size(L*W*Hmm) 491x260x490
Packing Size(L*W*Hmm) 545x315x550
N.W.(kg) 29 30 31.5 36
G.W.(kg) 32 33 34.5 39
Installation Method Tower
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) /
155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
Max AC charging current 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type
(selectable)
VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10ºC~40ºC
Storage temperature -15ºC~60ºC
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice
Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System Rechargeable Power Inverter with Battery Charger Function 4kw-7kw 48V/96V/192V, Solar Energy System
Previous: 
Next: 
Jiangmen Yuanhe Import. and Export. Co.,Ltd .
We are not only professional product manufacturer, but also good at project solution.
ABOUT YUANHE
Our team has 17 years of experiences in Emergency lightings industry .We are professional in Emergency lightings / Intelligent Central Control System of Emergency Lightings /Solar System.

QUICK LINKS

NEWSLETTER
Be the first to receive updates on new arrivals, special promos and sales.
 
copyright© 2022 Jiangmen Yuanhe Import. and Export. Co.,Ltd . All Rights Reserved Sitemap Support by Leadong